We – EPG Group the most significant gearbox & motors , couplings and gears manufacturing facility in China with 5 diverse branches. For far more information: Cell/whatsapp/telegram/Kakao us at: 0086~13083988828 13858117778083988828
Integrated push AC/DC PM Motor
Product Quick
E-MAX motor is the special created everlasting magnet synchronous motor based mostly on the IEC norm. E-MAX PMSM will be utilized for next generation which require far more power preserving product. Exceed IE4 variable pace AC motor (IEC60034-30-2-2016).
E-MAX motor is the initial era of DBS EC motor. E-MAX has led to produce the up coming era of technologies in motor effectiveness and overall performance.
E-MAX motor have two collection:
E-Max professional
IEC Body seventy one to 90 long lasting magnet synchronous motor integrated travel
E-Max Industrial
IEC Frame 71 to 132 everlasting magnet synchronous motor
E-Max Industrial series (ECI sequence)
Model | Frame | Rated | Output | Output | Highest |
dimension | torque | @1500rpm | @3000rpm | pace | |
(Nm)** | (kW) | (kW) | (rpm) | ||
T71ECI01X36 | 71 | 1.2 | .2 | .41 | 3600 |
T71ECI02X36 | 2.four | .forty one | .82 | 3000 | |
T71ECI03X18 | three.2 | .fifty five | – | 1800 | |
T90ECI03X36 | 90 | 3.two | .55 | one.one | 3600 |
T90ECI05X30 | four.8 | .75 | 1.5 | 3000 | |
T90ECI07X18 | seven | 1.1 | – | 1800 |
** The rated torque is based mostly on the motor cooling method. The element torque make sure you see information sheet.
E-Max Industrial Motor Drive Purpose
CW/CCW chooseStart-stop terminal0-10VDC pace controlRS485 ModbusSpeed hand handle by adjustable resistanceSpeed suggestions
E-Max Industrial series (EC series)
Model | Body | Rated | Output | Output | Maximum |
size | torque | @15000rpm | @3000rpm | speed | |
(Nm)** | (kW) | (kW) | (rpm) | ||
T71EC01X36 | 71 | 1.2 | .two | .forty one | 3600 |
T71EC02X36 | 2.4 | .41 | .82 | 3600 | |
T71EC03X36 | 3.two | .55 | 1.1 | 3000 | |
T90EC03X36 | 90 | 3.2 | .fifty five | one.one | 3600 |
T90EC05X36 | 4.8 | .75 | one.five | 3600 | |
T90EC07X36 | 7 | one.1 | two.2 | 3600 | |
T100EC10X36 | 100 | 9.5 | 1.five | 3 | 3600 |
T100EC14X36 | 14 | two.2 | four | 3600 | |
T100EC19X30 | 19.one | 3 | 5.five | 3000 | |
T132EC26X30 | 132 | twenty five.5 | 4 | 7.five | 3000 |
T132EC35X30 | 35 | five.5 | 11 | 3000 | |
T132EC48X30 | forty seven.7 | seven.five | 15 | 3000 | |
T132EC59X30 | 58.9 | nine.2 | eighteen.five | 3000 | |
T132EC70X30 | 70 | eleven | 22 | 3000 |
** The rated torque is based on the motor cooling technique. The detail torque you should see knowledge sheet.
Performance class
E-MAX motor has extremely-substantial performance the two at complete load and gentle load. The flat efficiency curve can preserve more energy when the motor generate the enthusiast or pump in HVAC subject.
Examine to IE4 motor efficiency course E-MAX
E-Max Business sequence
** Program effectiveness consist of the motor and travel performance.
E-Max Industrial collection
** Performance is only motor effectiveness.
Design amount nomenclature
T 90 EC 03 V 36 C2 B14 P T1
1 2 3 4 5 6 7 8 9 10
Place | Character | Description |
one | “T” | Merchandise system |
2 | “ninety” | Body size: IEC ninety# |
3 | “EC” | EC: everlasting magnet motor ECI: long term magnet motor with built-in drvie |
four | “03” | Rated torque |
5 | “V” | Cooling strategy: |
G = Basic functions, with supporter and admirer hood. IC411 | ||
V = Ventilation apps, with out supporter and fan hood. | ||
six | “36” | Maximum pace: 3600 rpm |
seven | C2 | Electrical power line relationship approach: T1 = Terminal box on prime T2 = Terminal box on NDE C1 = No terminal box, electricity line from housing C2 = No terminal box, energy line from NDE |
8 | B14 | Mounting method: B3, B14, B5, B34, B35 |
nine | P | P = Slid rail |
10 | T1 | Voltage code: T1: 3 period 360-440 V T2: 3 stage 200-240 V S1: 1 stage 200-240 V S2: 1 stage a hundred and fifteen V |
V ept consideration
PMSM must generate by the VSD. The motor can’t join to the regular AC electrical power straight. The VSD can be the business generate with vector management or PM motor handle manner. VSD need to be set up the right motor parameter (see beneath table). The detail parameters can be find in the product information sheet.
Energy select thing to consider
The energy and torque in earlier mentioned design checklist is the rated power or torque when the motor has not any cooling strategy (IC410). If the motor cooled by the wheel or the load the motor power can be bigger. The element managing assortment make sure you see element model info sheet. Under chart is a sample to make a decision the electrical power at distinct cooling problem.
Technological innovation
- Experienced on the supporter, pump, compressor and motion software with long lasting magnet motor style
- Motor model building and simulation, functionality calculation, sounds optimization
- Motor substance database: silicon metal, magnet, copper, aluminum
- Large precision examination equipment and instrument
Production and good quality management
- Automatic winding device to get much better regularity
- Electrical test tools
- Magnetic flux examining
Buyer Application
Customers & Exhibitions
The use of first gear manufacturer’s (OEM) element numbers or emblems , e.g. CASE® and John Deere® are for reference needs only and for indicating item use and compatibility. Our business and the listed replacement areas contained herein are not sponsored, authorized, or produced by the OEM.